RV900 series high-performance vector-type inverter adopts the international mainstream main control chip, which is characterized by fast computing speed, high control accuracy and powerful control performance; it uses power devices and raw materials of well-known brands and is processed with advanced manufacturing technology to meet the high-quality needs of our customers.
Item | Specifications | |
Basic Functions | Maximum Frequency | Vector Control:0~599.9Hz V/F Control:0~599.9Hz |
Carrier Frequency | 0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics. | |
Input Frequency Resolution | Digital Setting: 0.1Hz Analog Setting: 0.01V corresponding maximum frequency ×0.1% | |
Control Mode | Open Loop Vector Control(SVC),V/F Control | |
Startup Torque | 0.5Hz/150%(SVC) | |
Basic Functions | Speed Range and Precision | 1:100(SVC);±0.5%(SVC) |
Overload Capability | 150% rated current 60s,180% rated current 3s | |
Torque Boost | 0.1%~30.0% | |
V/F Curve | Line Type、Square Type | |
Acc. / dec Curve | Straight line or S curve acceleration and deceleration mode Acceleration and deceleration time range between 0.0 to 500.0s. | |
DC Brake | DC Brake Frequency:0.00Hz to maximum frequency. Brake time: 0.0s to 36.0s | |
Multi-speed Running | It can realize at maximum of 8 segments speed running via the control terminal. | |
Built-in PID | It is easy to realize process-controlled closed loop control system. | |
Over-voltage/current Stall Control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process. | |
Motor Over-temperature Protection | Acceptable motor temperature sensor input (PT100, PT1000) | |
Timing Control | Timing control function:set time range 0.0~6500.0Min | |
Bus Support | Support Site Bus:Modbus | |
Protection Function | It can implement power-on motor short-circuit detection, output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection, which can be turned on or shielded as required. | |
Running | Running Command Source | Operation panel reference, control terminal reference, and communication reference |
Target Frequency Source | Digital reference, analog signal reference, multi-segment speed reference, PI control reference, and communication reference | |
Control Signal Input Terminal | 5 digital input; 2 analog input,support 0~10V、4~20mA、0~20mA、20~0mA、20~4mA and 10~0V signal | |
Control Signal Output Terminal | 1 relay output, 2 digital output. 2 analog output,support 0~10V、4~20mA、0~20mA、20~0mA、20~4mA and 10~0V 0~20mA signal | |
Environment | Using Place | Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 0~4000m;Derating use when more than 1000m (decrease by 1% per 100 meters) | |
Ambient Temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9m/s (0.6g) | |
Storge Temperature | -20℃~+60℃ | |
IP Level | IP20 | |
Pollution Level | PD2 | |
Power Distribution System | TN, TT |